IES (Indoor)

Indoor Fixtures – Light Distribution, Lumens, Power, Efficacy, Zonal Lumens, Total Harmonic Distortion & IES File

IES (Direct/Indirect)

Indoor Fixtures – Light Distribution, Lumens, Power, Efficacy, Zonal Lumens, Total Harmonic Distortion & IES Files

IES (Outdoor)

Outdoor Fixtures – Light Distribution, Lumens, Power, Efficacy, Zonal Lumens, Total Harmonic Distortion & IES File

Sphere Test

Sphere Test – Lumens, Power, Efficacy, CCT, CRI, Ra, and R9, x, y, u, v, u1, v1, and Duv

In-Situ (ANSI/UL 1598)

Power, LED Case Temperature, Driver TC Temperature, and Electrical Data

Electrical

AC/DC Power, Voltage, Current, Total Harmonic Distortion and Power Factor

LM-79 (Indoor)

Indoor Fixtures – IES File, Light Distribution, Lumens, Power, Efficacy, Zonal Lumens, Total Harmonic Distortion, CCT, CRI, and R9, x, y, u, v, u1, v1, and Duv

LM-79 (Outdoor & Flood)

Outdoor & Flood Fixtures – IES File, Light Distribution, Lumens, Power, Efficacy, Zonal Lumens, Total Harmonic Distortion, CCT, CRI, and R9, x, y, u, v, u1, v1, Duv, and ISTM (In-Situ)

DLC Package (Indoor)

Indoor Fixtures – IES File, Light Distribution, Lumens, Power, Efficacy, Zonal Lumens, Total Harmonic Distortion, CCT, CRI, and R9, x, y, u, v, u1, v1, Duv, and ISTM (In-Situ)

DLC Package (Outdoor & Flood)

Outdoor & Flood Fixtures – IES File, Light Distribution, Lumens, Power, Efficacy, Zonal Lumens, Total Harmonic Distortion, CCT, CRI, and R9, x, y, u, v, u1, v1, Duv, and ISTM (In- Situ)

LM-82

Lumens, Power, Efficacy, CCT, CRI, and R9, x, y, u, v, u1, v1, Duv, & ISTM (In-Situ) all at +25°C, +25°C & Client Choice Temp (if desired)

Horticulture

PPF, PFFR, Spectral Quantum Distribution, Photosynthetic Photon Intensity Distribution, Photosynthetic Photon Efficacy, Lumens, Power, Efficacy, CCT, CRI, and R9, x, y, u, v, u1, v1, Duv

IP65

The amount of talcous dust is 2Kg per cubic meter of the test chamber volume. The dust injection rate is 2.0 Kg/m³ or 0.25 Kg/125L. H2O at 12.5 liters/minute through a 6.3 mm (1/4”) nozzle from a distance of 2.5 – 3 meters from all directions for at least 3 minutes.

IP66

The amount of talcous dust is 2Kg per cubic meter of the test chamber volume. The dust injection rate is 2.0 Kg/m³ or 0.25 Kg/125L. H2O at 100 liters/minute through a 12.5 mm (1/2”) nozzle from a distance of 2.5 – 3 meters from all directions for at least 3 minutes.

IP69K

The amount of talcous dust is 2Kg per cubic meter of the test chamber volume. The dust injection rate is 2.0 Kg/m³ or 0.25 Kg/125L. High temperature (up to 175°F/80°C) steam or water wash-downs at pressures of 1160 to 1450 psi at a rate of about 4 gallons per minute for at least 30 seconds from a distance between 4 and 6 inches at four different angle positions. (0°, 30°, 60°, 90°) while the DUT rotates at 5 rpm on a turntable.

IP6X

The amount of talcous dust is 2Kg per cubic meter of the test chamber volume. The dust injection rate is 2.0 Kg/m³ or 0.25 Kg/125L.

IPX5

H2O at 12.5 liters/minute through a 6.3 mm (1/4”) nozzle from a distance of 2.5 – 3 meters from all directions for at least 3 minutes.

IPX6

H2O at 100 liters/minute through a 12.5 mm (1/2”) nozzle from a distance of 2.5 – 3 meters from all directions for at least 3 minutes.

IPX9K

High temperature (up to 175°F/80°C) steam or water wash-downs at pressures of 1160 to 1450 psi at a rate of about 4 gallons per minute for at least 30 seconds from a distance between 4 and 6 inches at four different angle positions. (0°, 30°, 60°, 90°) while the DUT rotates at 5 rpm on a turntable.

UL-1598 Wet Location

A four hour, wet location test per section 16.5.2 of UL 1598: 2008 with 3 spray heads in accordance with section 19.17, maintaining 5 psi at each head.